ASTM D 3762, ”Standard Test Method for Adhesive-Bonded Surface Durability of Aluminum (Wedge Test)”
• Bonded aluminum double cantilever beam specimen is loaded by forcing a wedge between the adherends
• Wedge is retained in the specimen
• Assembly placed into a test environment
– Aqueous environment
– Elevated temperature
• Further crack growth is measured following a prescribed time period